Low Water Pressure in the Whole House | Hard Hat Rooter

Low Water Pressure in the Whole House? How to Find the Cause

Thin stream of water trickling from a faucet
Contents
  1. One Fixture or the Whole House
  2. Test the Pressure With a Gauge
  3. Low Water Pressure in the Whole House and the Regulator
  4. When the Gauge Reads Too High
  5. Galvanized Pipe Rusting Shut
  6. A Hidden Leak or a City Problem
  7. What We Check When We Come Out
  8. Frequently Asked Questions

Low water pressure in the whole house usually comes from one of four things: a failing pressure regulator, a main shutoff valve that isn’t fully open, old galvanized pipe that has rusted closed from the inside, or a hidden leak. If only one faucet or shower is weak, it’s that fixture. If every tap is weak, hot and cold, the problem is upstream, somewhere between the meter and the first branch inside the house.

You can narrow it down in about 15 minutes with a $10 pressure gauge from the hardware store. Here’s how, and what each answer points to. If you’d rather skip straight to a fix, our plumbing services page covers regulators, leak detection and repiping.

One Fixture or the Whole House

Start by checking a few taps in different rooms, hot and cold. That one test splits the problem in two.

  • One faucet or showerhead is weak. Usually a clogged aerator or showerhead. LA’s hard water leaves mineral scale that builds up in those small screens.
  • Only the hot side is weak, everywhere. Look at the water heater: sediment, a partly closed inlet valve, or scale in the lines. Our article on water heater lifespan in LA covers how hard water builds up in a tank.
  • Everything is weak, hot and cold. That’s a whole-house problem, and the rest of this article is for you.

Test the Pressure With a Gauge

A hose-bib pressure gauge screws onto any outdoor faucet. With nothing else running in the house, open the hose bib all the way and read the gauge. That number is your static pressure.

What’s normal? LADWP says most pressure regulators are set between 50 and 70 psi. If you’re reading well under that with the house quiet, something is restricting flow or the regulator is set or stuck low.

Then try the hose bib closest to where the water line enters the house, usually on the front or side wall, and one farther away. A big drop between the two points at the pipe in between.

Low Water Pressure in the Whole House and the Regulator

Most LA homes have a bell-shaped pressure regulator on the main line, close to where it comes up out of the ground. Its job is to bring street pressure down to a safe level. The California Plumbing Code, section 608.2, requires one wherever static pressure would exceed 80 psi, and LADWP notes that the property owner installs and maintains it.

Regulators wear out. When one fails, it can fail low, choking the whole house, or fail high, sending full street pressure into your pipes. Either way, it’s a replacement, not a repair. That’s common in foothill neighborhoods like Sierra Madre and Sunland, where street pressure can run high depending on elevation. LADWP calculates pressure for a given address from its ground elevation, and you can request that number free from its Water Distribution Services section.

LADWP also points out that older homes may not have a regulator at all, even where street pressure is above 80 psi, because they were built before the current code.

When the Gauge Reads Too High

Sometimes the test turns up the opposite problem: 90, 100 psi or more. A regulator that has failed open lets street pressure straight into the house. You may not notice it at the tap, but your pipes do.

High pressure means faster water moving through the pipe, and that wears copper from the inside. One Colorado water district found that nearly all the pinhole leaks reported in its neighborhood came from erosion caused by high velocity, most often from excessive pressure, and that the most common leak spot was right after the water line enters the house. Toilets that run on their own, faucets that drip, and pipes that bang when a valve shuts can all point the same way.

So if your gauge reads over 80, don’t celebrate the strong shower. Have the regulator checked.

Before you call anyone, walk out to the main shutoff and make sure it’s all the way open. After a repair or a water shutoff, it’s common for a valve to get left partly closed, and the whole house runs weak until someone notices.

Galvanized Pipe Rusting Shut

If your house was built before the 1960s and still has its original pipe, galvanized steel is a strong suspect. East Bay MUD explains that the zinc coating inside galvanized pipe wears away over time, and the iron underneath corrodes, building up deposits that block flow. The pipe looks fine from outside while the opening inside shrinks.

The giveaway is pressure that has gotten worse slowly over years, often with rust-colored water when a tap first opens. There’s no cleaning that fixes it. The answer is repiping, and most repipes take one to two days.

A Hidden Leak or a City Problem

A leak between the meter and the house can steal pressure, especially a big one under a slab or in the yard. Check the leak indicator on your water meter with every tap off. If it’s spinning, water is going somewhere.

And sometimes it isn’t your house at all. If the neighbors noticed the same drop on the same day, call your water utility first. Main breaks, repairs and work in the street can all lower pressure for a whole block.

What We Check When We Come Out

We start with a gauge at the main and a look at the regulator and shutoff, then work inward: the line to the house, the water heater, and the branches to each bathroom. If the pressure is fine at the main and weak inside, the pipe is the problem. If it’s weak at the main, it’s the regulator, the valve or the service line. We tell you what we found and give you a flat-rate price before we touch anything.

Hard Hat Rooter and Plumbing replaces pressure regulators, finds hidden leaks, and repipes older homes in copper or PEX across Los Angeles County. Call (855) 331-7788.

Frequently Asked Questions

What is normal water pressure for a house in Los Angeles?

LADWP says most residential pressure regulators are set between 50 and 70 psi. California’s plumbing code calls for a regulator wherever static pressure would exceed 80 psi. A hose-bib gauge reading inside that 50 to 70 range with nothing running is a healthy house.

How do I know if my pressure regulator is bad?

Signs include pressure that drops suddenly across the whole house, pressure above 80 psi on a gauge, banging pipes, or a regulator that leaks. A gauge test at a hose bib near the regulator tells you most of what you need to know. Replacing a regulator is a job for a plumber.

Can galvanized pipe cause low water pressure?

Yes. As the zinc coating inside wears away, the steel corrodes and builds up deposits that narrow the pipe. Pressure fades slowly over years, often with rusty water at first draw. Cleaning won’t fix it. Replacing the pipe does.

Why is my water pressure low only on the hot side?

When only hot water is weak throughout the house, the cause is usually at the water heater: sediment in the tank, a partly closed cold inlet valve, or scale in the hot lines. A plumber can check the heater and the lines leaving it.

Think you have a hidden leak?

Free estimates and a one-year warranty on parts and labor.